Overview
Questions
Question: Can I connect more than one magnetic contact to the transmitter of the DS90?
Answer: Yes, you can connect several magnetic contacts. The DS90 sensor has an extra input. If you want to connect more than one extra magnetic contact, you need to connect them in serial.
Question: Can I connect other alarm contacts to the transmitter of the DS90?
Answer: Yes, you can connect any type of NC (normally closed) contact to the extra input on the DS90 (e.g. smoke detectors with a NC relay contact). The extra alarm contact has its own zone number on the console.
Question: Does the tamper function of the DS90 also work on my SC2200/SC2700/SC2800 alarm system?
Answer: No, the tamper function is a specific function on the SC9000 alarm system (SafeGuard and TotalGuard).
Question: My DS90 causes a false alarm, what could be the problem?
Answer: Sometimes there are electrical currents in aluminium door and window frames. These can trigger the DS90. If this happens, it is best to use an MS90 motion detector for the room instead.
Also, check whether the distance between the transmitter and the magnetic contact is not too large.
Specification
Power: 2x AAA battery
RF range: 15 - 30m through walls and floors
Dimensions: 76 x 42 x 20mm
Frequency: 433,92 MHz
Our product discussion box is a great way for you to view other peoples' feedback about products on UK Automation, and add your own.
We hold a large stock of items in our UK warehouse, so no waiting extra time for deliveries from outside the UK
Direct telephone support (no call centres, speak directly to us) during office hours, and email support quite often out of hours too!
All products are covered by our 30 day money back guarantee. If you're not happy, return the goods to us in the condition you received them for a full refund.
Not in a hurry? Our super saver delivery option gives you free delivery within 5 - 7 days (although many customers receive their items much quicker!)